Key moments

When you press play, the animation slows down and then freezes for 6 to 8 seconds at the turning points of each tab: in Titration at each half-equivalence point (pH = pKa for a weak acid or base), each equivalence point, and the moment the indicator is half changed, with the indicator error in mL; in Buffers when the pH has moved one unit and when the buffer component is used up; in Speciation at each pKa, where two species are equal; in Water and temperature at 25 °C and at body temperature, with the neutral pH; and in Make a solution when a pour carries the pH through 7. Every moment is solved from the tab’s own equilibrium model, so they move when you change the acid, base, concentrations, indicator or buffer. The solution is ringed in red and the caption pulses with a countdown bar. Red diamonds on the timeline mark the moments; “Next ▸” jumps to the next one, and “Key moments” turns the pauses off. Dragging the time slider or playing at 2× skips them.

Make a solution

Fill the beaker from the reagent shelf: strong and weak acids and bases, salts, and polyprotic acids, in any combination. The pH meter reads the exact answer, found from the charge balance (the sum of positive charges equals the sum of negative charges), which works for any mixture. Beside it, the panel shows the textbook shortcut worked through step by step, and says whether that shortcut holds. The two usually agree, and where they don’t (very dilute acids, the 400 and 5% rules failing, amphiprotic salts) the difference is the lesson.

Buffers

Choose a buffer system and a target pH, and the lab gives the recipe: how much of the acid and its conjugate base for the volume and total concentration you set. Henderson–Hasselbalch, pH = pKa + log([A⁻]/[HA]), is compared with the exact pH. The buffer capacity β is the amount of strong base per litre needed to raise the pH by one unit; it is largest when pH = pKa and useful within pKa ± 1. Challenge the buffer by adding 0.10 M NaOH or HCl with the timeline and watch it hold until one component runs out, against plain water shown dashed. Dilution barely moves the pH but lowers β.

Titration

A burette adds titrant to the analyte in the flask; the timeline is the volume added. The curve is drawn exactly, with each equivalence point marked. At half-equivalence a weak acid gives pH = pKa. At equivalence the pH is 7 only for a strong acid with a strong base; with a weak acid the product is a weak base and the pH is above 7. Choose an indicator and see whether its colour change, shown as a band, falls on the steep part of the curve. The first derivative turns each equivalence point into a peak.

Speciation

The fraction α of each form of an acid against pH. Two neighbouring forms are equal where pH = pKa. For polyprotic acids such as phosphoric acid, each form dominates over its own pH window, which is why one acid can make buffers at three different pH values.

Water and temperature

Water ionises more as it warms, so Kw rises and the pH of neutral water falls: about 7.47 at 0 °C and 6.13 at 100 °C. It stays neutral, since [H₃O⁺] = [OH⁻]; only the number 7 belongs to 25 °C.

Practice

Generated problems: strong and weak acids and bases, buffers, the half-equivalence point, and choosing a buffer system. Every answer is checked against the exact engine, and the feedback shows the method.

Settings used

pKa values at 25 °C from standard tables; Kw against temperature from standard data. The calculation treats concentrations as activities (ideal solutions). Real measured pH differs, because ions interact: typically by a few hundredths in dilute solutions and by more in concentrated or highly charged ones. For example, 0.05 M potassium hydrogen phthalate is a pH 4.00 calibration standard, while the ideal calculation gives 4.18. Particles in the beaker are drawn on a logarithmic scale so that very small and large concentrations both show.